Mission-critical data center design & engineering MCP server. Provides cooling load calculations, power redundancy analysis, tier classification assessment, and commissioning workflow tools for AI agents.

Package Exports

  • datacenter-mcp-server
  • datacenter-mcp-server/dist/index.js

This package does not declare an exports field, so the exports above have been automatically detected and optimized by JSPM instead. If any package subpath is missing, it is recommended to post an issue to the original package (datacenter-mcp-server) to support the "exports" field. If that is not possible, create a JSPM override to customize the exports field for this package.

Readme

datacenter-mcp-server

Mission-critical data center engineering tools for AI agents. 8 professional-grade calculation engines covering cooling, power, GPU thermal optimization, UPS/battery sizing, tier classification, and commissioning workflows.

Built on the Model Context Protocol (MCP) standard — works with Claude Desktop, Cursor, Windsurf, Cline, and any MCP-compatible client.

Quick Start

Claude Desktop

Add to your claude_desktop_config.json:

{
  "mcpServers": {
    "datacenter": {
      "command": "npx",
      "args": ["-y", "datacenter-mcp-server"]
    }
  }
}

Cursor / Windsurf

Add to your MCP settings:

{
  "datacenter": {
    "command": "npx",
    "args": ["-y", "datacenter-mcp-server"]
  }
}

HTTP Mode (Remote)

TRANSPORT=http PORT=3001 API_KEY=your-secret npx datacenter-mcp-server

Tools

dc_calculate_cooling_load

Calculate ASHRAE-compliant cooling requirements for any data center facility. Inputs include IT load, redundancy level, climate zone, altitude, and humidity targets. Returns tonnage, airflow, chilled water capacity, and energy estimates.

dc_analyze_power_redundancy

Analyze electrical distribution from utility feed through UPS, PDU, and rack-level power. Supports N, N+1, 2N, and 2N+1 redundancy configurations with efficiency and cost analysis.

dc_assess_tier_classification

Evaluate facility design against Uptime Institute Tier I-IV standards. Identifies compliance gaps and provides actionable upgrade recommendations.

dc_generate_commissioning_plan

Generate L1-L5 commissioning workflows with phase sequencing, test procedures, and documentation requirements per ASHRAE Guideline 0.

dc_analyze_rack_density

Analyze rack power density configurations from 5 kW to 100+ kW per rack. Covers cooling strategy selection, weight loading, and power distribution.

dc_gpu_cooling_optimizer

Optimize cooling infrastructure for GPU/AI workloads (H100, A100, H200, B200, GB200). Calculates thermal loads, recommends cooling strategies (air, rear-door, direct liquid, immersion), sizes CDUs, and projects energy savings.

dc_ups_battery_sizing

Size UPS modules and battery systems with N/N+1/2N/2N+1 redundancy. Compares VRLA vs lithium-ion with 10-year TCO analysis, floor space estimates, and weight calculations.

dc_reference_lookup

Query ASHRAE standards, Uptime Institute tier requirements, and industry best practices for data center design and operations.

Engineering Standards

All calculations comply with:

  • ASHRAE TC 9.9 thermal guidelines
  • Uptime Institute Tier Standard topology
  • NFPA 70 / NEC electrical code
  • ASHRAE Guideline 0 commissioning

Development

# Install dependencies
npm install

# Build
npm run build

# Run tests (264 tests across 7 suites)
npm test

# Start in stdio mode (MCP default)
npm start

# Start in HTTP mode
npm run start:http

# Inspect with MCP Inspector
npm run inspect

Architecture

src/
  index.ts          # MCP server entry point, tool registration
  types.ts          # TypeScript interfaces for all tools
  constants.ts      # Engineering constants and reference data
  middleware.ts      # Express middleware (auth, rate limiting, CORS)
  schemas/          # Zod validation schemas per tool
  services/         # Calculation engines per tool
tests/              # Jest test suites (264 tests)

License

MIT - NextGen Mission Critical