JSPM

node-red-contrib-atipsae

3.0.1
  • ESM via JSPM
  • ES Module Entrypoint
  • Export Map
  • Keywords
  • License
  • Repository URL
  • TypeScript Types
  • README
  • Created
  • Published
  • Downloads 1
  • Score
    100M100P100Q37639F
  • License Apache-2.0

Advantech IPS-AE Nodes

Package Exports

    This package does not declare an exports field, so the exports above have been automatically detected and optimized by JSPM instead. If any package subpath is missing, it is recommended to post an issue to the original package (node-red-contrib-atipsae) to support the "exports" field. If that is not possible, create a JSPM override to customize the exports field for this package.

    Readme

    node-red-contrib-atipsae

    Node-RED node for ADVANTECH IIoT UNO-IPS2730-AE.

    Notice that an Advantech IIoT Platform SDK have to be installed to make this node works correctly. Advantech IIoT Platform SDK download link is shown below:

    Windows: https://github.com/Advantech-IIoT/Platform-SDK/tree/master/windows/bin

    Linux: https://github.com/Advantech-IIoT/Platform-SDK/tree/master/linux/bin

    Installation

    Use npm command to install this package locally in the Node-RED modules directory

    npm install node-red-contrib-atipsae

    or install it globally with the command

    npm install node-red-contrib-atipsae -g

    Description

    You must use the Node-RED with UNO-IPS2730-AE.

    Example

    You can try demo flow demo.json via import function from Node-RED editor. demoflow

    The inputs must be msg.payload.UPSInputLostDelay and msg.payload.UPSCutOffDelay which are numeric.

    msg.payload.UPSInputLostDelay is a number which is the DC Input Lost detection duration(sec).

    msg.payload.UPSCutOffDelay is a number which is the DC-OUT cut-off delay time(minutes).

    Another input msg.payload.port is COM port name which is used to connect with UPS.


    There are 3 outputs, Emergency, Status and Response.

    The Emergency output is a string and consists of the following.

    "DC-IN is Losted"

    "Battery Over Temperature"

    "Battery Gauge is Lost Connection"

    "EEPROM Access Fail"

    "DC-IN is Over Voltage"

    "The DC-Out Cut-Off trigger"

    "Restores power to IPS-AE DC-IN"

    The Status output is a javascript object format in msg.payload and the object contents are as follows

    fwversion : DEVICE firmware version

    ips : the status of DEVICE. 1 is ready and 0 is not ready

    dcin : the status of DC-IN. 1 is ready and 0 is not ready

    battery : the status of BATTERY. 1 is ready and 0 is not ready

    inputlostdelay : the DC Input Lost detection duration(sec)

    utoffdelay : the DC-OUT cut-off delay time(minutes)

    atterylife : BATTERY life(minutes) at the present rate of discharge. "65535" is BATTERY charged.

    emperature : BATTERY temperature(celsius)

    maxtemperature : It's the max temperature(celsius) of BATTERY from the system started.

    batteryvoltage : It's the the BATTERY voltage(mV).

    capacity : BATTERY capacity(%)

    The Response. output is a string to describe the input result.


    Tested Platform

    • Windows 10 Enterprise LTSC with node.js 18.14.1

    History

    • 3.0.1 - June 2023 : update for NODE_MODULE_VERSION=108 (C++ addons use Node-API)
    • 2.0.1 - November 2019 : update for NODE_MODULE_VERSION=64 (C++ addons use Native Abstractions for Node.js)
    • 1.1.7 - October 2017 : Initial Release

    License

    Copyright 2019 ADVANTECH Corp. under the Apache 2.0 license.